DISEÑO Y CUANTIFICACIÓN DEL AISLAMIENTO ACÚSTICO DE UNA VENTANA ACÚSTICA CON VENTILACIÓN (DESIGN AND QUANTIFICATION OF THE ACOUSTIC INSULATION OF AN ACOUSTIC WINDOW WITH VENTILATION)

Pistas Educativas

Aarón Manuel Salas Cortés Universidad Autónoma Metropolitana-Azcapotzalco
Dulce Rosario Ponce Patrón Universidad Autónoma Metropolitana-Azcapotzalco
Felipe Orduña Bustamante Universidad Nacional Autónoma de México, Ciudad Universitaria
Ricardo Dorantes Escamilla Universidad Nacional Autónoma de México, Ciudad Universitaria
Ernesto Rodrigo Vázquez Cerón Universidad Autónoma Metropolitana-Azcapotzalco
Laura Angélica Lancon Rivera Universidad Autónoma Metropolitana-Azcapotzalco

Resumen

Resumen Se diseñó y evaluó una ventana acústica basada en un resonador de Helmholtz con el objetivo de permitir el paso de aire sin comprometer el aislamiento sonoro. El sistema consiste en una ventana doble de 0.69 x 0.69 m con una separación de 0.05 m entre hojas, sus aperturas son proyectantes desfasadas. El diseño busca optimizar la ventilación manteniendo un alto nivel de aislamiento acústico. La evaluación experimental se realizó en la cámara de transmisión de la UNAM, donde se midió el índice de reducción sonora, utilizando una fuente omnidireccional y micrófonos ubicados en diversos puntos. Se obtuvo un Rw de 11 dB (-1; -1) que demuestra la viabilidad del sistema como alternativa pasiva para espacios con requerimientos de ventilación y control acústico. Este estudio presenta solo los resultados de la evaluación acústica contribuyendo al desarrollo de una solución arquitectónicas que equilibra, ventilación y aislamiento sonoro. Palabras Clave: Aislamiento sonoro, cámara de transmisión, pérdida de transmisión, resonador de Helmholtz, ventana acústica. Abstract An acoustic window based on a Helmholtz resonator was designed and evaluated with the aim of allowing air passage without compromising sound insulation. The system consists of a double window measuring 0.69 x 0.69 m with a 0.05 m gap between panes, featuring offset projecting openings. The design seeks to optimize ventilation while maintaining a high level of acoustic insulation. The experimental evaluation was conducted in the transmission chamber of the National Autonomous University of Mexico (UNAM), where the sound reduction index was measured using an omnidirectional source and microphones placed at various positions. An Rw value of 11 dB (-1; -1) was obtained, demonstrating the feasibility of the system as a passive alternative for spaces requiring both ventilation and acoustic control. This study presents only the results of the acoustic evaluation, contributing to the development of architectural solutions that balance ventilation and sound insulation. Keywords: Acoustic window, Helmholtz resonator, sound insulation, transmission chamber, transmission loss.

Datos de publicación

Cita esta publicación

Comprueba el estilo que requiere tu institución o revista.

Aarón Manuel Salas Cortés; Dulce Rosario Ponce Patrón; Felipe Orduña Bustamante; Ricardo Dorantes Escamilla; Ernesto Rodrigo Vázquez Cerón; Laura Angélica Lancon Rivera. (2026). DISEÑO Y CUANTIFICACIÓN DEL AISLAMIENTO ACÚSTICO DE UNA VENTANA ACÚSTICA CON VENTILACIÓN (DESIGN AND QUANTIFICATION OF THE ACOUSTIC INSULATION OF AN ACOUSTIC WINDOW WITH VENTILATION). Pistas Educativas, 47(151). https://pistaseducativas.celaya.tecnm.mx/index.php/pistas/article/view/4132

Fuentes y trazabilidad

Se conserva la procedencia de los datos y se da prioridad a la revista cuando existe información editorial.

Licencias declaradas por las fuentes

Licencia en el registro de origen

Descargar ficha bibliográfica

El PDF contiene los metadatos y el enlace al trabajo original.