Resumen

Resumen El objetivo del presente trabajo es mostrar cómo se efectuó la adquisición y procesamiento de señales en sensores montados sobre una barra Kolsky polimérica; se utilizó software y tarjeta de adquisición de datos de NI National Instruments. Los datos se exportan a una hoja de Excel para su posterior análisis, la adquisición de datos de las galgas extensiométricas se realizó con ensayos al vacío, lo que quiere decir que son ensayos sin probeta. Los ensayos al vacío permiten observar qué porcentaje de error hay entre el pulso incidente y transmitido, lo que indica si hay amortiguamiento del pulso incidente, si no hay error quiere decir que las barras poliméricas denominadas también viscoelásticas, cumplen con la relación de pulso incidente es igual al pulso transmitido, sin probeta. Con probeta la relación sería pulso incidente más pulso reflejado es igual al pulso transmitido. Para facilitar el cálculo del error en este articulo solo se efectúan ensayos al vacío. Palabras clave: LabVIEW, Pulso incidente, Pulso reflejado, Pulso transmitido. Abstract The objective of this paper is to show how the acquisition and processing of signals on sensors mounted on a polymer Kolsky bar was carried out; NI National Instruments data acquisition software and card was used. The data is exported to an Excel sheet for further analysis, the acquisition of strain gauge data was performed with vacuum tests, which means that they are tests without test specimen. The vacuum tests allow to observe what percentage of error there is between the incident and transmitted pulse, which indicates if there is dampening of the incident pulse, if there is no error means that the polymeric bars also called viscoelastic, comply with the incident pulse ratio is equal to the transmitted pulse, without test specimen. With test specimen, the ratio would be incident pulse plus reflected pulse equal to the transmitted pulse. For ease of calculation of the error in this article only vacuum tests are performed. Keywords: LabVIEW, incident pulse, reflected pulse, transmitted pulse.

Datos de publicación

Cita esta publicación

Comprueba el estilo que requiere tu institución o revista.

María del Carmen Tinajero Campos; Álvaro Sánchez Rodríguez; Luis Alejandro Alcaraz Caracheo; Horacio Orozco Mendoza; Ignacio Alejandro Irausquin Castro. (2021). AQUISICIÓN Y PROCESAMIENTO DE SEÑALES OBTENIDAS DE UN ENSAYO CON BARRA KOLSKY POLIMERICA (ADQUISITION Y PROCESSING OF SIGNALS FROM AN EXPERIMENT WITH POLIMERIC KOLSKY BAR). Pistas Educativas, 43(140). https://pistaseducativas.celaya.tecnm.mx/index.php/pistas/article/view/2608

Fuentes y trazabilidad

Se conserva la procedencia de los datos y se da prioridad a la revista cuando existe información editorial.