In recent years, the rise of renewable energy has driven the development of new power electronics topologies. Simulation, particularly Hardware-In-the-Loop (HIL), has become essential for testing control algorithms under conditions close to real hardware. However, commercial HIL systems are expensive, and custom solutions require significant time and technical expertise. This work presents a semi-custom HIL solution for a three-phase ANPC inverter using LabVIEW FPGA and the CRIO-9067 platform, achieving a 1 μs computation time and less than 1% error at a load current of 0.5 A per phase. The results demonstrate a viable alternative that balances accuracy, flexibility, and development efficiency.