Instituto Tecnológico de Celaya Tecnológico Nacional de México
ITC Investigación ITC
Explorar publicaciones
Artículo · 2023 · Catálogo consolidado

Quantitative Upper Limb Assessment With Natural User Interface in Children With Hemiparesis

IEEE Access

Celia Francisco-Martínez ORCID Department of Electronics Engineering, National Technological Institute of Mexico in Celaya, Celaya, Mexico
Karla S. Morales-Soto Department of Early Stimulation and Occupational Therapy, Association for People with Cerebral Palsy (APAC), Celaya, Mexico
Juan Prado-Olivarez ORCID Department of Electronics Engineering, National Technological Institute of Mexico in Celaya, Celaya, Mexico
Javier Díaz-Carmona Department of Electronics Engineering, National Technological Institute of Mexico in Celaya, Celaya, Mexico
José A. Padilla-Medina ORCID Department of Electronics Engineering, National Technological Institute of Mexico in Celaya, Celaya, Mexico
Alejandro I. Barranco-Gutiérrez ORCID Department of Electronics Engineering, National Technological Institute of Mexico in Celaya, Celaya, Mexico
Carlos A. Herrera-Ramírez Department of Robotics Engineering, Polytechnic University of Guanajuato, Guanajuato, Mexico
Alejandro Espinosa-Calderón ORCID Regional Center for Optimization and Device Development (CRODE), National Technology of Mexico in Celaya, Celaya, Mexico

Resumen

Quantitative, efficient, and accurate measurement of upper limb motor performance is relevant for monitoring upper limb progress in daily activities of people with cerebral palsy, which is helpful to define an appropriate rehabilitation procedure. Currently, motion capture sensors using a Natural User Interface (NUI) are the most feasible solutions due to the low-cost implementation, portability, and effectiveness for upper limb motion analysis. A quantitatively assessment study of the upper limb motor performance for children with spastic hemiparesis using the NUI Kinect v2 sensor is described in this paper. The study participants were eighteen children with an average age of 8.28 ± 2.32 years having a Manual Ability Classification System level I and II. The assessment was done for each participant before and after the application of a Modified Constrained-Induced Movement Therapy (mCIMT) applied five days a week along twelve weeks. According to obtained results significant differences (p<0.05) in the Fugl-Meyer Assessment (FMA) score for motor performance in abduction movement of upper limb between the first and last sessions were quantitatively detected. The described NUI assessment method helped to quantitatively show that the applied therapy sessions were effective to improve upper extremity motor performance. Additionally, the upper limb movements motorically limited after the rehabilitation therapy were also identified. The main contribution of the described NUI assessment method is its potential use as a quantitative measurement tool, which might be used by specialists to objectively diagnose and consequently define an appropriate rehabilitation therapy for patients with hemiparesis.

Datos de publicación

Cita esta publicación

Comprueba el estilo que requiere tu institución o revista.

Celia Francisco-Martínez; Karla S. Morales-Soto; Juan Prado-Olivarez; Javier Díaz-Carmona; José A. Padilla-Medina; Alejandro I. Barranco-Gutiérrez; Carlos A. Herrera-Ramírez; Alejandro Espinosa-Calderón. (2023). Quantitative Upper Limb Assessment With Natural User Interface in Children With Hemiparesis. IEEE Access, 11, 35080-35088. https://doi.org/10.1109/access.2023.3264599

Fuentes y trazabilidad

Se conserva la procedencia de los datos y se da prioridad a la revista cuando existe información editorial.

Licencias declaradas por las fuentes

https://creativecommons.org/licenses/by-nc-nd/4.0/

Descargar ficha bibliográfica

El PDF contiene los metadatos y el enlace al trabajo original.